800*1100*1800mm W*H*D Dimensions and ISO Certified Chitherm Hrf230-05 Hot Air Box Furnace for Heat Treatment Processes
1. Application:
Widely used in the debinding processes of LTCC and MLCC manufacturing.
2. Technical Specification: - Rated temperature: 400°C.
- Maximum temperature: 450°C.
- Effective dimensions: 550*660*640mm (W*H*D).
- Temperature uniformity: ±3°C.
- Temperature stability: ±1°C.
- Sintering atmosphere: Air.
- Heating elements: Stainless steel heaters.
- Compact design with small footprint.
- The chamber adopts a 12-grid structure forming 12 airflow channels. Airflow volume is adjusted by controlling the opening angle of air outlet panels in each channel, achieving high temperature uniformity.
- Tested temperature uniformity within ±3°C.
3. Delivery List
| Item | Note | Qty. |
Basic Components | Furnace | | 1 unit |
inspection certificate | Certificate of major outsourced components | 1 SET |
Technical Documents | Instructions, technical documents of the major outsourced parts, etc | 1 SET |
Key Components | Heating Element | Stainless steel heater | 1 SET |
Touch Screen | | 1 SET |
Temperature Controller | | 1 SET |
Blower | | 1 PC |
Circulation Fan | | 1 SET |
Spare Parts | SSR | | 1 pcs |
Heating Element | Stainless steel heater | 1 PC |
4. Facility Requirements - Environmental Conditions: temperature: 0~40ºC, humidity ≤ 80%RH, no corrosive gas, no strong airflow disturbance;
- Atmosphere Conditions: dry, clean, oil-free compressed air, working pressure of 0.2- 0.4MPa, gas consumption of 10 -20m3/h;
- Ventilation System: non-contact access to the user pumping system, pumping capacity is greater than 20 m3/h
- Ground Requirements: horizontal, no obvious vibration, load-bearing> 300 Kg/m2;
- Power Condition(TBD): capacity > 16kVA, 3-phases 5-lines, voltage 220/380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
- Installation Site: 1000mm*1500mm*3000mm(W*D*H), with an installation area greater than 1.5m2.