Hefei Chitherm Equipment Co., Ltd

Manufacturer from China
Verified Supplier
1 Years
Home / Products / High Temperature Box Furnace /

380V Laboratory High Temperature Box Furnace For Metal Heat Treatment

Contact Now
Hefei Chitherm Equipment Co., Ltd
Visit Website
City:hefei
Province/State:anhui
Country/Region:china
Contact Person:Mrzang
Contact Now

380V Laboratory High Temperature Box Furnace For Metal Heat Treatment

Ask Latest Price
Video Channel
Model Number :HBF300-13
Range of Applications :Industrial
Type :Electric Holding Furnace
Usage :Steel Molding
Fuel :Electric
Effective Chamber Dimensions :560*780*700mm(W*H*D)
Atmosphere :Air
Transport Package :Wooden Package
Specification :1570*2050*1830mm (W*H*D)
Trademark :Chitherm
Origin :China
HS Code :8514101000
Supply Ability :Customized
Customization :Available
Certification :ISO
Place Style :Vertical
Place of Origin :China
Brand Name :Chitherm
MOQ :1
Price :Negotiable
Packaging Details :Customized
Delivery Time :Customized
Payment Terms :Customized
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Hbf300-13 Temperature Box Furnace Suitable for Various Laboratories Effective Chamber Dimensions of 560*780*700mm

Overview
The HBF300-13 high-temperature box furnace uses silicon carbide rods inserted in ceramic tubes as heating elements. The heating elements are arranged in the upper, middle, and lower sections, ensuring uniform temperature distribution in the furnace chamber. It is easy to operate and suitable for various laboratory processes.

Specifications
Model
: HBF300-13 High-Temperature Box Furnace
Rated Temperature: 1250ºC
Maximum Temperature: 1300ºC
Effective Dimensions: 330×200×660mm (W×H×D)
Chamber Material: Inner layer made of alumina products, outer layer using ceramic fiber inorganic standard board
Heating Elements: Silicon carbide rods in ceramic tubes
Chamber Temperature Uniformity: ±5ºC (at 1250ºC constant temperature)
Number of Temperature Control Segments: 9
Temperature Control Points: Upper, middle, and lower 3-point control
Alarm and Protection: Interlock for heating and furnace door operation, over-temperature, thermocouple break, and low-pressure audible and visual alarms
Surface Temperature Rise: ≤40ºC
Maximum Heating Power: ≤70kW
Power Requirements: Three-phase, 220/380VAC, 50Hz, greater than 90kVA, phase-shift control

380V Laboratory High Temperature Box Furnace For Metal Heat Treatment
380V Laboratory High Temperature Box Furnace For Metal Heat Treatment

Equipment Handover Checklist

Table 1 - Delivery Overview
Name Main Content Quantity
Primary Configuration Kiln Main Unit The core equipment of the industrial electric kiln 1 Unit
Certification of Inspection Documentation certifying the conformity of components 1 Set
Technical Documentation Manuals and technical files accompanying major purchased components 1 Set

Key Components

Ceramic Tube for Silicon Carbide Rod Protective tube for the heating element 1 Set
Firing Plate or Burner Plate Component for supporting and firing materials 1 Set
Temperature Control Module (Yamatake or Equivalent) Precision temperature control system 1 Unit
Thermocouple (Type S) Temperature sensor with S-type calibration 3 Pieces
Touchscreen Interface HMI (Human-Machine Interface) for kiln control 1 Unit
Programmable Logic Controller (Siemens) Automation control system 1 Unit
Power Regulator (Taiwan Techsil) Device for adjusting power output 1 Set
Blower Fan Component for air circulation or forced convection 1 Unit

Spare Parts

Silicon Carbide Rod Heating element for the kiln 2 Rods

Equipment Installation and Usage Conditions

  1. The equipment must be installed indoors, with an ambient temperature of 0ºC to 40ºC. The indoor environment should be free of flammable gases, corrosive gases, and steam.
  2. The equipment requires a floor area of at least 5 square meters, with a working space length of at least 2.5 meters, width of at least 2 meters, and height of at least 3 meters. The foundation should be solid and level, and the furnace weighs approximately 850kg.
  3. The power supply for the furnace must be a three-phase five-wire AC power line, 380±10%V, 50±2%Hz. This power line should be dedicated, and large power conversion equipment such as welding machines, electric furnaces, and metal cutting machines should not be connected to the same distribution.
  4. The equipment must be reliably grounded.
  5. The equipment's intake pressure should be 0.2 to 0.4Mpa.380V Laboratory High Temperature Box Furnace For Metal Heat Treatment

Inquiry Cart 0