High Temp. Box Furnace Chitherm Hbf52-17ohigh for Ceramic Sintering 1620*1960*1220mm W*H*D
1. Applications:
High-temperature sintering processes are widely used for ITO targets, microwave ferrites, magnetic materials, electronic components, ceramic filters, and similar products.
2. Mainly Specifics: - Rated Temp.: 1650ºC
- Max Temp.: 1700ºC
- Effective Dimensions: 350 * 300 * 500mm(W*H*D)
- Heating Method: U-shaped Silicon Molybdenum Rod.
- Process Atmosphere: Air/Oxygen
- Temperature Control Stability: ±1ºC, with PID parameter self-tuning function
- Temperature Uniformity: better than ±5ºC (insulation 2 hours at 1650ºC test)
- Thermocouple: B Type
- Temperature control points: 1
- Number of Temp. Profiles: 4*16 steps
- Exhaust chimney: Located at the top of the furnace chamber, with an automatically opening/closing chimney cover.
- Alarm protection: Audible and visual alarms for over-temperature, thermocouple break, and other faults, with power cut-off protection upon over-temperature alarm.
- Max Heating Power: 25kW
- Insulation Power: ≤ 10kW
- Heating Speed: RT~1200ºC≤5ºC/min,1200~1700ºC≤2ºC/min
- Surface Temperature Rise: ≤ 35ºC
- Weight: about 950kg
- Furnace Dimensions: about 1620*1960*1220mm (W*H*D);
- Appearance Color: light gray
3. Delivery List |
| Item | Note | QTY |
Basic Compositions | Furnace | | 1 PC |
Certificates of Inspection | Furnace and major purchased components | 1 Set |
Technical Documents | Furnace specifications, technical documents of major purchased components, etc | 1 Set |
Key Parts | Heating Elements | U-shaped Silicon Molybdenum Rod | 1 Set |
Thermocouple | THERMOWAY, B Type | 1 PC |
Temperature Controller | | 1 Set |
PLC | | 1 Set |
Monitor | Proface touch screen | 1 Set |
Spares | SSR | | 2 Set |
U-shaped Silicon Molybdenum Rod | | 2 PC |
4. Facility Requirements 4.1 Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong airflow disturbance. 4.2 Process air conditions: clean, dry, oil-free compressed air, pressure 0.2 - 0.4Mpa, gas consumption 2 - 6m3 /h. 4.3 Ventilation system: non-contact access to the user pumping system, pumping capacity is greater than 10m3 /h; 4.4 Ground requirements: level, no obvious vibration, bearing capacity > 300Kg/m2 . 4.5 Power conditions: capacity greater than 34kVA, 3 phases 5 lines, voltage 220/380V, frequency 50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green; 4.6 Installation site: 2000mm*3000mm*1500mm (W*H*D), installation area greater than 3m2.