Hefei Chitherm Equipment Co., Ltd
Visit Website
City:hefei
Province/State:anhui
Country/Region:china
Contact Person:Mrzang
Contact Now

1100 Ordm C Medium Temperature Nitrogen Furnace Electrical Box For Heating

Ask Latest Price
Video Channel
Model Number :MBF40-10O
Range of Applications :Industrial
Type :Electric Holding Furnace
Usage :Ceramic Sintering
Fuel :Electric
Atmosphere :Air
Effective Chamber Dimensions :330*200*660mm(W*H*D)
Furnace Chamber Size :360*460*800mm(W*H*D)
Rated Temperature :850°c
Thermocouple Type :K
Transport Package :Wooden Packaging
Specification :1150*1970*1460mm(W*H*D)
Trademark :Chitherm
Origin :China
HS Code :8514101000
Supply Ability :Customized
Customization :Available
Certification :ISO
Place Style :Vertical
Place of Origin :China
Brand Name :Chitherm
MOQ :1
Price :Negotiable
Packaging Details :Customized
Delivery Time :Customized
Payment Terms :Customized
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
MBF40-10O 1100 ordm C Medium Temperature Box Furnace for Heating 330*200*660mm Effective Chamber Dimensions Electric Furnace
1.Model:MBF40-11O Medium Temperature Atmosphere Box Furnace

2.Application Fields: Primarily used for the sintering process of lithium battery cathode and anode materials, and also suitable for sintering processes of magnetic materials, electronic components, ceramics, and other products.

3. Mainly Specifics:
1. Rated Temperature: 850°C.
2. Maximum Temperature: 1100°C
3. Furnace Opening Size: 360mm × 220mm (Width × Height).
4. Furnace Chamber Size: 360mm × 460mm × 800mm (Width × Height × Depth).
5. Effective Size: 330mm × 200mm × 660mm (Width × Height × Depth).
6. Sagger Specification: 330mm × 100mm × 330mm (Width × Height × Depth).
7. Loading Method: Sagger supported by SiC rollers, double-layer and double-row arrangement.
8. Heating Elements: Silicon carbide rods inside ceramic tubes.
9 .Thermocouple Type: K-type.
10. Temperature Control Points: Upper and lower points for control, middle point for measurement.
11. Temperature Control Method: Imported temperature control module, control accuracy ±1°C, with PID parameter self-tuning function.
12. Heating Stages: 9 stages.
13. Oxygen Content Detection: Equipment reserved with oxygen content detection port (optional oxygen analyzer).
14. Pressure Detection: Real-time display of furnace pressure via digital differential pressure gauge.
15. Furnace Temperature Uniformity: ±3°C (tested at 850°C constant temperature with empty furnace and saggers, one thermocouple ring at the center of each sagger).
16. Exhaust Method: Exhaust chimney designed at the top of the furnace chamber, manually adjustable exhaust size.
17. Maximum Heating Power: ≤25kW
18.Surface Temperature Rise of Furnace Body: ≤40°C.
19 .Alarm Protection: Interlock between heating and furnace door operation, audible and visual alarms for overtemperature, thermocouple break, and low pressure.
20 .Reference External Dimensions: 1150mm × 1970mm × 1460mm (Width × Height × Depth, excluding chimney), actual dimensions subject to the specific product.

1100 Ordm C Medium Temperature Nitrogen Furnace Electrical Box For Heating

1. - Furnace frame
2. - Chimney
3. - Furnace chamber
4. - Furnace door
5. - Heating element
6. - Sagger (a type of ceramic container used in kilns)
7. - Roller bar (used in kilns for moving ceramics during the firing process)

4.Delivery List
Item Note QTY
Basic Compositions Furnace 1 PC
Certificates of Inspection Furnace and major purchased components 1 Set
Technical Documents Furnace specifications, technical documents of major purchased components, etc 1 Set
Key Parts Heating Elements ceramic tube-encased silicon carbide rod 1 Set
Temperature Controller Azbil 1 Set
touch screen 1 Set
Spares silicon carbide rod 1 PC

5. Facility Requirements
1 .Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong
airflow disturbance.
2 .Process air conditions: 99.999% purity nitrogen, pressure 0.2 - 0.4Mpa, gas consumption 6 - 18m3 /h.
3 .Ventilation system: non-contact access to the user pumping system, pumping capacity is greater
than 20m3 /h;
4 .Power conditions: capacity greater than 34kVA, 3 phases 5 lines, voltage 220/380V, frequency
50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green;

5 .Installation site: 2500mm×2000mm×3000mm (W×H×D), installation area greater than 5m2.