Vertical Industrial Electric Furnace Bf580-17 Type Temperature Bell Furnace for Industrial Applications at Place Style
1. Application:
The equipment is widely used in high-temperature sintering processes for advanced ceramics, magnetic materials, electronic ceramic components, and other products.

2. Technical Specification: - Effective Size: 1200×600×800mm (D×H×W)
- Rated Temperature: 1700ºC
- Maximum Temperature: 1750ºC
- Number of Temperature Control Points: 2 points
- Furnace Temperature Uniformity: +5ºC within the effective space, tested under no-load conditions at a 1700ºC platform for 2 hours
- Temperature Control Accuracy: ±1ºC (during high-temperature platform stage)
- Control Method: Phase-Shift Control
- Heating Elements: Heating Elements
- Control Instrument: Imported Intelligent Temperature Controller from Japan
- Alarm Protection: Audible and visual alarms for over-temperature, thermocouple break, overload, over-travel, deviation, etc.
- Thermocouple Type: B Index
- Atmosphere System: Air / Oxygen
- External Dimensions: 2880×3600×2240, excluding tracks and control cabinet
- Number of Gas Inlet Points: 20 points in total on opposite sides of the furnace body (10 points on each side)
- Operating Power Supply: 220/380VAC 50Hz
- Maximum Power: 120kW
- Equipment Weight: Approximately 8000kg
3. Delivery List Table 1 Delivery list |
| Item | Note | Qty. |
Basic Components | Furnace | | 1 SET |
Inspection Certificates | Certificates of major outsourced components | 1 SET |
Technical Documents | Instructions, technical documents of the major outsourced parts, etc | 1 SET |
Key Components | Silicon molybdenum rod | U-shaped silicon molybdenum heater | 1 SET |
Power regulator | | 1 SET |
Thermocouple | | 1 SET |
temperature controller | Island Electric, Dahua Qianye, Eurofins and other similar brands | 1 SET |
PLC | SIEMENS | 1 SET |
Touch Screen | 15 cun | 1 SET |
Spare Parts | Heating Element | U-shaped silicon molybdenum heater | 1 PC |
4. Equipment Normal Operating Conditions - Environmental Conditions: temperature: 0~40ºC, humidity≤ 80%RH, no corrosive gas, no strong airflow disturbance;
- Atmosphere Conditions: dry, clean, oil-free compressed air, working pressure of 0.4- 0.8MPa, gas consumption of 10 -30 m3/h;
- Ventilation System: Non contact access user exhaust system, with an exhaust capacity greater than 50 m3/h
- Ground Requirements: horizontal, no obvious vibration, load-bearing> 1000 Kg/m2;
- Power Condition(TBD): capacity > 160kVA, 3-phases 5-lines, voltage 220 / 380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
- Installation Site: 6000mm×4000mm×4000mm(D×W×H), with an installation area greater than 24m2.