High Temp. Bell Furnace 1740*2780*2505mm W*H*D for Ceramic Sintering within Chitherm Bf125-17
1. Application:
This equipment is mainly designed for electronic ceramic materials, magnetic materials, ceramic filters, etc. require high uniformity of temperature field or multi-species small batch production occasions.
2. Technical Specification: - Rated Temp.:1600ºC
- Max Temp.:1700ºC
- Effective Dimensions:550mm*500mm*550mm(D*W*H)
- Heating Method: U-shaped silicon molybdenum heater
- Thermcouple:R-Type
- Temperature Control: 1 Point
- Temp. Set Accuracy: ±1ºC(flat temp. insulation)
- Temp. Control Mode:control module imported from Japan with PID
- Heat-up Rate :400 ~ 1000≤5ºC/min,1000 ~ 1500≤2ºC/min
- Temp. Uniformity: ± 5ºC (empty furnace insulation test 2hours under 1500ºC)
- Maximum Lifting Trip:800mm
- Lift System: the equipment lifting operation system adopts three-point control, which can be stopped at any time, with stable and reliable operation
- Loading Weight ≤ 1000kg (with firing furniture and products)
- Exhaust System : 1 exhaust chimney is set at the top for exhaust gas emission
- Alarm System : with over-temperature, broken couple, overload, over-range, deviation and other sound and light alarm protection function
- Maximum Heating Power:50kW
- Insulation Power:≤25kW
- External Dimensions: 1740*2780*2505mm(D*W*H) (without control cabinet)
- Appearance Color: Light gray.

2. Delivery List Table 1 Delivery list |
| Item | Note | Qty. |
Basic Components | Furnace | | 1 SET |
Inspection Certificates | Certificates of major outsourced components | 1 SET |
Technical Documents | Instructions, technical documents of the major outsourced parts, etc | 1 SET |
Electrical purification furnace | | 1 SET |
Key Components | Silicon molybdenum rods | U-shaped Model MK1800 (Diameter Range: 6-12mm) | 1 SET |
Touchscreen | | 1 SET |
Thermocouple | R-Type | 1 SET |
Temperature Control Module | | 1 SET |
Spare Parts | Heating Element | U-shaped silicon molybdenum heater | 1 PC |
3.
Equipment Normal Operating Conditions - Environmental Conditions: temperature: 0~40ºC, humidity≤ 80%RH, no corrosive gas, no strong airflow disturbance;
- Atmosphere Conditions: dry, clean, oil-free compressed air, working pressure of 0.2- 0.4MPa, gas consumption of 10 - 30 m3/h;
- Ventilation System: non-contact access to the user pumping system, pumping capacity is greater than 35 m3/h
- Ground Requirements: horizontal, no obvious vibration, load-bearing> 600 Kg/m2;
- Power Condition(TBD): capacity > 70kVA, 3-phases 5-lines, voltage 220 / 380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
- Installation Site:3800mm*2650mm*3500mm(D*W*H), with an installation area greater than 12m2.