Electric Chitherm Bf260-16 High Temp. Bell Furnace for Air Atmosphere and Electric Fuel at High Temperature
1. Application:
Widely used in the adhesive sintering process of zirconia ceramics, magnetic materials, electronic ceramic components and other products.
2. Technical Specification: - Rated Temp.:1500ºC
- Max Temp.:1600ºC
- Effective Dimensions:720mm*500mm*720mm(D*W*H)
- Heating Method:MoSi2 heating element
- Thermcouple:B-Type
- Temperature Control: 1 Point
- Temp. Set Accuracy: ±1ºC(flat temp. insulation)
- Temp. Control Mode:The Japanese Daiwa Chino Programmable Temperature Controller features PID auto-tuning functionality.
- Temp. Uniformity: ± 5ºC (empty furnace insulation test 2hours under 1500ºC) .
- Maximum Heating Power:85kW
- Insulation Power:≤40kW
- Program Control: SCR Control Module;
- Lifting Mechanism: Lead Screw Drive Elevation System;
- Control Method: Phase Angle Control;
- Operating Atmosphere: Air;
- Exhaust System: Top-mounted exhaust stack for effluent discharge;
- Protection Functions: Audible & visual alarm system for over-temperature, motor overload, and over-travel conditions;
- External Dimensions: 1950*3600*3100mm(D*W*H) (without control cabinet)
- Appearance Color: Light gray.
3. Delivery List Table 1 Delivery list |
| Item | Note | Qty. |
Basic Components | Furnace | | 1 SET |
Inspection Certificates | Certificates of major outsourced components | 1 SET |
Technical Documents | Instructions, technical documents of the major outsourced parts, etc | 1 SET |
Control Cabinet | 1000*2000*600mm(W*H*D) | 1 SET |
Key Components | Silicon molybdenum rod | | 1 SET |
Thermocouple | B-Type | 1 SET |
Temperature controller | Japanese Daiwa Chino | 1 SET |
Spare Parts | Heating Element | Silicon molybdenum rod | 1 PC |
4.Equipment Normal Operating Conditions - Environmental Conditions: temperature: 0~40ºC, humidity≤ 80%RH, no corrosive gas, no strong airflow disturbance;
- Atmosphere Conditions: dry, clean, oil-free compressed air, working pressure of 0.2- 0.4MPa, gas consumption of 10 - 30 m3/h;
- Ventilation System: non-contact access to the user pumping system, pumping capacity is greater than 30 m3/h
- Ground Requirements: horizontal, no obvious vibration, load-bearing> 500 Kg/m2;
- Power Condition(TBD): capacity > 120kVA, 3-phases 5-lines, voltage 220 / 380V, frequency 50Hz. Fire line: yellow, green, red, Zero line: blue, Ground line: yellow-green;
- Installation Site:4000mm*3500mm*4000mm(D*W*H), with an installation area greater than 14m2.