Industrial Electric Holding Furnace Hrf512-05n Nitrogen Drying Furnace with Wide Range of Applications
1. Applications:
Used in thermal treatment processes such as product drying and debinding.
2. Mainly Specifics: - Rated Temp.: 400ºC
- Max Temp.: 500ºC
- Effective Dimensions: 800 × 800 × 800mm(W×H×D)
- Heating Method: Stainless Steel Heater.
- Process Atmosphere: Nitrogen.
- Temperature Control Stability: ±1ºC, with PID parameter self-tuning function.
- Temperature Uniformity: better than ±5ºC (insulation 1 hour at 400ºC test).
- Thermocouple: Type K.
- Temperature control points: 1
- Temperature measurement points: 1 point.
- Process Steps: 4 × 10 steps.
- Exhaust: One exhaust port on top,DN50,The exhaust vent size can be manually adjusted.
- Alarm System: over temperature, thermocouple failure and other abnormal conditions will activate sound and light alarm protection
- Max Heating Power: 24kW..
- Insulation Power: ≤ 12kW.
- Surface Temperature Rise: ≤ 35ºC.
- Weight: about 1200kg.
- Furnace Dimensions: about 1500×1930×2000mm (W×H×D,No chimney included).
- Appearance Color: light gray
- Exhaust gas treatment: VOCs in the exhaust gas are thermally decomposed through an electric purification furnace.

3. Delivery List |
| Item | Note | QTY |
Basic Compositions | Dryer | | 1 PC |
Certificates of Inspection | Dryer and major purchased components | 1 Set |
Technical Documents | Manual instructions, technical documents of major purchased components, etc | 1 Set |
Key Parts | Heating Elements | Stainless Steel Heater | 1 Set |
Temperature Controller | | 1 Set |
Monitor | Touch screen | 1 Set |
Spares | SSR | | 1 PC |
4. Facility Requirements 4.1 Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong airflow disturbance. 4.2 Process air conditions: 99.999% purity nitrogen, pressure 0.2 - 0.4Mpa, gas consumption 10m3 /h. 4.3 Ventilation system: non-contact access to the user pumping system, pumping capacity is greater than 15m3 /h; 4.4 Ground requirements: level, no obvious vibration, bearing capacity >300Kg/m2 . 4.5 Power conditions: capacity greater than 32kVA, 3 phases 5 lines, voltage 220/380V, frequency 50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green; 4.6 Installation site: 2000mm×3000mm×3000mm (W×H×D), installation area greater than 6m2.