Hrf512-07 800 times 800 times 800mm w*h*d Nitrogen Atmosphere Hot Air Decarburisation Furnace with Stainless Steel Heater
1. Applications:
Powder materials, magnetic materials, ceramics, glass, metals, plastics, and post-3D printing drying, curing, debinding, tempering, annealing, aging, preheating, and age hardening.
2. Mainly Specifics: - Rated Temp.: 650ºC
- Max Temp.: 700ºC
- Effective Dimensions: 800 × 800 × 800mm(W×H×D)
- Heating Method: Stainless Steel Heater.
- Process Atmosphere: Air.
- Temperature Control Stability: ±1ºC.
- Temperature Uniformity: better than ±5ºC (insulation 1 hour at 650ºC test).
- Thermocouple: Type K.
- Temperature control points: 1
- Temperature measurement points: 1 point.
- Process Steps: 4 × 16 steps.
- Exhaust: One exhaust port on top,DN50,The exhaust vent size can be manually adjusted.
- Alarm System: over temperature, thermocouple failure and other abnormal conditions will activate sound and light alarm protection
- Max Heating Power: 36kW.
- Heating rate: ≤5°C/min (operable at 1°C/min).
- Insulation Power: ≤ 18kW.
- Surface Temperature Rise: ≤ 35ºC.
- Weight: about 1200kg.
- Furnace Dimensions: about 1500×1930×2000mm (W×H×D,No chimney included).
- Appearance Color: light gray.
3. Delivery List |
| Item | Note | QTY |
Basic Compositions | Dryer | | 1 PC |
Certificates of Inspection | Dryer and major purchased components | 1 Set |
Technical Documents | Manual instructions, technical documents of major purchased components, etc | 1 Set |
Key Parts | Stainless Steel Heater | | 1 Set |
Temperature Controller | | 2 Set |
Touch Screen | | 1 Set |
circulating fan | | |
Spares | SSR | | 1 PC |
Stainless Steel Heater | | 1 Set |
Seal gasket | | 2 Set |
4. Facility Requirements 4.1 Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong
airflow disturbance.
4.2 Inlet water conditions: Clean and non-corrosive, water temperature ≤ 23 °C, inlet pressure 0.2-0.4 MPa, flow rate approximately 2-6 L/min. 4.3 Ventilation system: non-contact access to the user pumping system, pumping capacity is greater
than 15m3 /h;
4.4 Ground requirements: level, no obvious vibration, bearing capacity >300Kg/m2 .
4.5 Power conditions: capacity greater than 50kVA, 3 phases 5 lines, voltage 220/380V, frequency
50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green;
4.6 Installation site: 2000mm×3000mm×3000mm (W×H×D), installation area greater than 6m2.